Pharma question



100+ Quality Assurance Interview Questions Pharma

Quality assurance is a very important part of manufacturing good quality products in pharmaceuticals. so all of the pharmacy graduates want to apply for a job in the department of quality assurance. For this, they have to crack the interview. so we have design 100+ most important Quality Assurance Interview Questions in pharma manufacturing.

QA interview Questions for Fresher and Experienced

Q1. Define quality assurance?

Ans: QA is a broad range of concept contains all the matters that individually or collectively affect the quality of a product. QA mainly concentrated on planning and documenting the procedures to assure quality.

Q2.What is Documentation?
Ans) Documentation is all types of written procedures, records, and instructions, Quality control test records with procedures involved in all manufacturing activities of drug products.

Q3. During In-process Q.A Checks, what needs to be checked?

Ans: 1) Environmental Monitoring 2) Measured values obtained from the process equipment (ex: temperature, RPM, etc.) 3) Measured values obtained from persons (ex: timings, entries, etc.) 4) Process attributes (Ex: weight, hardness, stability, etc.

Q4. What are In process checks?
Ans) In-process checks are checks carried out during an activity to monitor and, where necessary, to adapt the process in order to ensure that the product conforms to its specification.

Q5. What needs to be checked during AHU validation?
Ans: During AHU validation, the following tests shall be carried out
1) Air velocity & number of air changes
2) Airflow pattern (visualization)
3) Differential pressure, temperature, and RH
4) Static condition area qualification
5) Dynamic condition qualification
6) Non-viable count
7) Microbial monitoring
8) Area recovery and power failure study
Q6. What precautions shall be taken while collecting in-process samples?

Ans: While collecting in-process samples, protect the sample from contamination while sampling (Don’t collect samples with bare hands). use gloves while sampling.

Q7. What are the factors which influence tablet hardness?
Ans: 1.force applied for compression 2.Binder quantity (More binder quantity more hardness)
3.Presence of moisture in granules.

Q8. If the leak test falls during In process checks what needs to be done?
Ans: Immediately stop packing process and check for
1.Sealing temperature
2.check knurling quality and, change in printed foil, etc.
3.Check & quarantine the isolated quantity of packed goods from last passed in the process.
4.Collect random samples & do a retest.
5.Blisters from the leak test passed containers shall allow going further and rest must de-blistered/ Defoil accordingly.

Quality Assurance Interview Questions related to documentation

Q9. What is 21 CFR part 11?
Ans: Title 21 CFR Part 11 of the Code of Federal Regulations deals with the Food and Drug Administration (FDA) guidelines on electronic records and electronic signatures in the United States.

Q10. What Is a Change control?
Ans: Change Control is a general term describing the process of managing how changes are introduced into a controlled System. Into validation, this implies how changes to the validated system are made. Change control is needed to demonstrate to regulatory authorities that after system modifications, validated systems remain under control after system changes.

Q11. What Is SOP?
Ans: A Standard Operating Procedure (SOP) is a certain type of document that describes in a step-by-step outline form how to perform a particular task or operation. To ensure that tasks are conducted consistently and appropriately, everybody in an organization must follow the same procedures. Many organizations have a broad range of SOPs that illustrate how to execute various tasks. In many companies, technicians and operators are trained in how to follow individual SOPs and their training record specifies SOPs they are trained on and are authorized to use.

Q12. Tell me about the content of the SOP
Ans) 1. Objective or Purpose/Aim
2.Scope
3. Responsibility
4.Procedure
5. Precautions
6. Annexure
7. Abbreviations
8. Reference
9. Revisions History
Q13. What do you know about stability studies?
Ans: These are necessary for developing pharmaceutical products. The influence of environmental factors (e.g. light, humidity, temperature, etc.) on active pharmaceutical ingredients (API) or pharmaceutical ingredients (API) may be evaluated.

Q14. Expand BMR and BPR
Ans: BMR – Batch Manufacturing Record, prepared as a written file during the manufacturing a product by writing, Step by the step manufacturing process and details about batch recorded here. For every BMR, BPR-Batch Packaging Record, is held. BPR depends on packaging operation.

Q15. Difference between validation and calibration?
Ans: Validation provides written evidence to ensure that a particular method or operation continuously develops a product with predetermined requirements and quality credits. It is performed according to validation protocol.
Calibration denotes that equipment produces the values in specified limits by comparing the values produced by a standard. It Is done according to the calibration SOP.

Q16. Tell any five countries with their regulatory authorities?
Ans) India Central Drugs Standard Control Organization (CDSCO) USA – United States Food and Drug Administration (USFDA) UK Medicines and Healthcare products Regulatory Agency (MHRA) Japan- Ministry of Health Labour and Welfare (MHLW) Australia- Therapeutic Goods Administration (TGA)

Q17.What position of the oblong tablet to be placed in hardness tester to know the hardness
Ans) it should be lengthwise because its breakage probability is more in this position.

Q18.Why we calibrate an instrument on a particular interval?
Ans) because it can be possible for instruments to drift out of accuracy after qualification. so it needs to requalify the instrument at a specific time interval.

Q19. What checks shall be carried out while calibration of Disintegration Test apparatus.
Ans) Strokes number per minute. It shall be a 29-32 cycle per minute.
Temperature by using probes and a standard thermometer. It shall be 37±1°c
Traveling distance by the basket. It shall be 53-57 mm.

Q20. Why positive pressure kept in the corridor, not in the process area?
Ans) the different pressure gradient is very important at different locations to avoid cross- Contamination of a product through the air.

Q21. Recommended storage condition for empty hard gelatin capsule
Ans) it should be 15-25°C and 35-5/% RH.

Q22. What shall be the DT Temperature recommendation for dispersible tablet
Ans) 25 plus minus 1°C (IP) and 15-25°C (BP)

Q23.What is a Change Request?

Ans) Change Control is a general term that describes the process of managing the implementation of changes in a controlled system. Into validation, this means how changes are made to the validated system. change Control is made to demonstrate to the Regulatory authority. that the validated system remains under Control after the system change. Change Control systems are a favorite target of regulatory auditors because they vividly demonstrate an organization’s capability to Control systems.

Q24. Difference between validation and calibration?
Ans: Validation provides written evidence to ensure that a particular method or operation reliably develops a product with predetermined requirements and quality credits. It is performed according to validation protocol.
Calibration denotes that equipment produces the values in specified limits by comparing the values produced by a standard. It Is done according to the calibration standard operating procedure.

Q25. Tell me the time required for long-term and accelerated stability testing?
Ans: long term study 12 months
Accelerated stability 6 months.

Q26.What is SISPQ?
Ans: Safety, integrity, strength, purity, and Quality.

Q27. Which Flurosence material use in BIN Washing PQ.
Ans: Riboflavin

Q28.Which class of area Required for Tablets and Capsule Manufacturing?
Ans: Class D

Q29. What is positive pressure?
Ans: The atmospheric pressure which is higher than the immediate surrounding areas usually measured in inches of water or pascal.

Q30. What is the schedule- M?
Ans: Good Manufacturing Practice and Requirements of premises of the plant, waste disposal, and equipment.
GMP is divided into two separate parts:
GMP I for Factory premises
GMP II For plant and Equipment.

Q31.What is Deviation
Ans: A deviation is an unexpected event that accrues during the ongoing operation/activity/Documentation/entries at any stage of receipt, storage and Manufacturing, analysis and distribution of drugs products/Intermediate/Raw materials/ packing materials. The deviation is to be reported as and when events occur and to be investigated for impact analysis.

Q32. What is VMP?
Ans: VMP Means Validation master plant. It’s about brief information about Qualification, Validation, and calibration of equipment, instruments, and system. VMP types documents providing information on the company’s Validation work program.
Responsibility related to VMP should be stated.

Related: Technical pharmaceutical interview questions answers

Q33.What are Market Complains?
Ans) A complaint is any expression of dissatisfaction with a product or service marketed. Any written/ genuine verbal communication received directly from any customer, retailer, distributor, healthcare professional, regulatory agency, patient (Consumer), or field staff, regarding the safety, identity, strength, purity, quality, shortages or any other such complaint shall be treated as a market complaint.

Q34. What is Product recall?:

Ans) Removal or correction of marketed products for the reasons relating to deficiencies in quality, safety or efficacy, including labeling considered to be in violation of the laws.

Q35. Vendor Qualification?

Ans) New Vendor: Manufacturer identified by Formulation Development or purchase department as a manufacturer to supply of a specific material from a specific manufacturing site.

Approved Vendor: Manufacturer of raw material, primal and printed packaging material, which has been approved by QA to supply specific material from a specific site, based on the cGMP.

Q36. Cleaning Validations?

Ans: DEFINITION: Cleaning Validation is the documented evidence that an approved cleaning procedure will provide equipment that is suitable for processing medicinal products.

Q37. ANNUAL PRODUCT QUALITY REVIEW (APQR):

Ans: Documented regular periodic or rolling quality reviews of all licensed medicinal products with the objective of verifying the consistency of the existing manufacturing process to highlight any trends and to identify product and process improvements or weaknesses for licensed medicinal products the appropriateness of current specifications for both starting materials and finished products.

Q38. What is the limit for “individual unknown Impurity” in API as per ICH Q2A?
Ans: The limit of the “Any individual unknown Impurity” is not more than 0.1%

Q39. What are the class-1 solvents as per ICH Q3C?
Ans:. Benzene – .2
Carbon tetrachloride -4ppm
1,2 Dichloroethane – 5ppm
1 ,1 Dichloroethene – 8ppm
1 , 1 , 1 -Trichloroethane-1500 ppm

Q40. What is the specific gravity of Methylene chloride?
Ans: The specific gravity of Methylene chloride is 1.308 gm/ml

Q41.Suppose your pharma area is class 100000, then what are the maximum light and sound levels as per guidelines?
Ans) light level: not less than 300 lux.
Sound level: not more than 80 decibels.

Q42. What is the name of the instrument, which is used for measuring vacuum (in Tars) during high vacuum distillation?
Ans: Macleod gauge

Q43. is the cGMP requirement only for personnel in the manufacturing?

Ans: No, this requirement is for each and every employee of the organization who must know relevant cGMP requirements in his/her area.

Q44. Why we conduct the training?
Ans: It brings awareness and helps employees to become competent.

Q45.India belongs to which Climate Zone?
Ans: India comes under Climate Zone III (Know as Hot dry Zone) and Zone IVb ( know as Hot/Higher humidity)

Q46.What is force degradation or stress testing:
Ans: Force degradation also knows as stress testing and a drug is degraded Forcefully by applying artificial methods.
It helps to know about Impurities that develop during the storage of drug products in various environmental conditions. Forced degradation study depends upon the product and the type of dosage form. Solid, liquid, and injection have different procedures for the stress study.

Q47.Tell me about Qualifications and their flow
Ans: Design Qualifications, installation Qualifications, Operational Qualifications, and Performance Qualification. Flow=URS- FAT-SAT-DQ-IQ-OQ-PQ.

Q48.What is a Critical Quality Attribute?
Ans: it is chemical, physical, biological, and microbiological characteristics that should be under limits, range to ensure the quality of the products.

Q.49 What is OOS (Out of Specification)?
Ans: A result that falls outside established acceptance criteria which are established in official compendia and/or by company documentation.
OR
OOS is the comparison of one result versus predetermined specification criteria.
Example of OOS (Out of Specification):
The specification limit for the assay is 90.0-110.0 % w/w of the label claim.
For a selected batch, the result obtained 85.2 % w/w – This result’s out of the specification limit and this is often called OOS.
Q50. What is OOT (Out of TREND)?
Ans: Results of a drug substance of a selected batch, which is within the specification limit but a similar result in comparison to other batches of a similar drug substance, is falling outside the typical of the results of all compared batches.
Or
specification result may be within limits but showing a significant change from the historical results.
Example of OOT (Out of TREND):
The result obtained 95.8 % w/w. Although the results are well within the specifications, we should always compare the result with the previous batches trend. If we found the typical value of the trend as 99.0 % w/w then this batch result (95.8 % w/w) is named out of trend.

Quality Assurance Interview Questions related to process Area?

Q51. What is relative humidity?

Ans: it is differentiated as in the ratio between the amount of water vapor in a particular volume of air provided temperature and the temperature at which maximum amount of water vapor that the air can possess.

Q52. if temperature or RH of area goes out of limit what action you takes?

Ans: immediately stop the line, informed to the responsible department to rise the maintenance requisition slip. ensure that all the intermediate materials are properly covered.

Q53. How to stop cross-contamination in a area?

Ans: By ensuring proper gowning and material transfer procedure and controlled manpower movement in the area, maintaining Differential pressure is also important to controlled cross-contamination.

IPQA pharma interview Question:

Q54 What is process validation?
Ans: EMA Definition “documented evidence that the method, operated within established parameters, can perform effectively and reproducibly to provide a medicinal product meeting its predetermined specifications and quality attributes.”
USFDA Definition “The evaluation of data and collection, from the process design stage throughout production stage, to consistently delivering a quality product” based on establishes scientific evidence.

Q55 consistent with regulatory guidelines (USFDA), what are the stages of process validation?

Ans: Process validation involves a series of activities happening over the lifecycle of Drug products and process. There are three stages for process validation activities.
Stage 1 — Process Design: The commercial manufacturing process is defined during this stage based on knowledge gained through development and scale-up activities.
Stage 2 — Process Qualification: During this stage, the method design is evaluated to work out if the method is capable of reproducible commercial manufacturing.
Stage 3 — Continued Process Verification: Ongoing assurance is gained during routine production that the method remains during a state of control.

Q56 Tell How many batches took for the process validation?
Ans: The EMA draft guideline states “a minimum of three consecutive batches”, with justification to be provided (there are some exceptions to the current statement).
The US FDA guidance states that the quantity of batches must be sufficient to supply statistical confidence of the method . It is a subtle, but important distinction in the approaches.

Q57 Explain the strategy for process validation of solid dosage forms?

Ans: The use of different lots of raw materials should be included. i.e., active drug substance and major excipients.

  • Batches should be run serial and on different days and shifts (the latter condition, if appropriate). Batches should be manufactured within the equipment and facilities designated for eventual commercial production.
  • Critical process variables should be set within their operating ranges and will not exceed their upper and lower control limits during process operation. Output responses should be within finished product specifications.
  • Failure to satisfy the wants of the Validation protocol with reference to process input and output control should be subjected to process requalification

Q58 What is Validation Protocol?
Ans: A written plan of actions stating how process validation will be conducted; it will specify who will conduct the various tasks and define testing parameters; sampling plans, testing methods, and specifications; will specify the product and its characteristics, and equipment to be used. It must specify the number of batches and acceptance criteria to be used for validation studies; and who will sign/approve Disapprove the conclusions derived from such a scientific study.

Q59 What should be process validation protocol content?

  • General information
  • Objective
  • Background/Pr- validation Activities, Summary of development and tech transfer (from R&D or another Site) activities to justify in-process testing and controls; any Previous validations.
  • List of equipment and their qualification status
  • Facilities qualification
  • Process flow charts
  • Manufacturing procedure narrative
  • List of critical processing parameters and important excipients
  • Sampling, tests, and specifications
  • Acceptance criteria

Q60. what should be the blend sample size in In-process validation studies?

Ans: lx – 3x dosage unit range on a case to case basis. As per USFDA guidance, sampling sizes are often increased from lx -10x with adequate scientific justification.

Q61. How many sampling points should be considered for collecting blend samples According to USFDA guidance?
Ans: According to USFDA guidance At least 10 sampling locations to be considered.
In the case of connective blenders At least 20 locations are recommended to adequately validate (ex: ribbon blender)

Q62 What will be the reason for within location variance of blend data?

Ans: Inadequacy of blend mix, sampling error, or agglomeration

Q63. What is the difference between EMA & US guidelines on process validation?
Ans: EMA US Definition “documented evidence that the process, operated within established parameters, can perform effectively and reproducibly to produce a medicinal product meeting its predetermined specifications and quality attributes.”
Definition “The evaluation of data and collection, from the process design stage throughout production stage, to consistently delivering a quality product” based on establishes scientific evidence.” The EMA draft guideline states “a minimum of three consecutive batches”, with justification to be provided (there are some exceptions to the present statement).

The US FDA guidance states that the number of batches must be sufficient to supply statistical confidence of the method. It is a subtle, but important distinction in the approaches. The EMA draft encourages the use of the product development activities but is less sanctioned on requirements. The US FDA guidance emphasizes documenting the event phase as a part of PV. The EMA guideline specifically allows the utilization of CPV to exchange traditional validation efforts.

US FDA approach does not place a high emphasis on CPV, and requires all three stages of process validation to be fully addressed, regardless of whether contemporary or traditional methods are utilized. The US FDA guidance considers equipment and process design, as well as equipment qualification as part of the overall process validation effort. The EMA guideline sees the process as independent from equipment and facility. Currently, the EMA still relies on Annex 15 of the GMP guide for instruction on equipment qualification.

Q64 During process validation Why hopper challenge study is performing?
Ans: To evaluate the effect of vibrations during compression on blend uniformity, a hopper study shall be carried out.

Q65 What are the critical process variables in the coating?
Ans: Pan RPM, inlet & exhaust temperature, spray rate, gun distance, and air pressure.

Q66 Why blending may be a critical parameter in tablet manufacturing?
Less blending will result in non-uniform distribution of drug and poor flow whereas more blending will result in de-mixing leading to non-uniform distribution of drug and an increase in disintegration time.

     